Fire Shutters | Fire Roller Shutters by Westwood Security
Westwood Security Fire Shutters offer 1, 2, 3 and 4 hour rated Fire Roller Shutters. All of our Fire Rated Shutters are fully tested and certified to BS EN 1634.
Established in 1994, Westwood have many satisfied Fire Shutters customers nationwide. Our Fire Rated Roller Shutters are manufactured by specialists. With our satellite bases around the country we offer an unrivalled national reach for Fire Shutter insallations. We promise a quick turnaround for new Fire Shutters and in emergency situations will do our best to offer a same-day Fire Shutters replacement service. For supply only we can offer a next day overnight Fire Shutter delivery service.
Please inform us if you propose to use the roller shutters for example a high frequency usage like a car park in the iniatial quotation process. Our fire shutters are tested to BS EN 1634-1 at Exova Warrington Fire Global Safety. There are many areas where fire resistance testing and fire certification is required by national and international building regulations.
Our Fire Shutter installation vehicles are covered by Navman tracking systems, provided by Competitive Tracking. For your peace of mind, we know where all of our teams are at all times, so in real time we can tell you exactly when your Fire Shutters will be with you!
Call Now For An Instant Fire Shutter Quote:
0161 272 9333 (North) | 0207 873 2390 (South)
Fire Shutters - Technical Details
There are three main methods of automatic operation. Firstly a fusible link involves the use of solder as connection in the circuit: heat radiated from a nearby fire causes the solder to melt and this activates the door.
Secondly a fire relay means that the Fire Shutter or Fire Door is connected to the fire alarm system. When the alarm is sounded, the Fire Shutter activates. Finally, a delayed Audio/Visual Warning used in connection with the Fire Shutter is connected to the alarm system, and operates usually with a time delay very similarly to a fire relay. During this delay an additional alarm is sounded, warning those in close proximity to the door that is about to close, thus allowing them to exit the affected area.
Building regulations require that openings in fire resisting walls or partitions must have a door with an equivalent fire rating to that of the wall or partition.
Option 3 - Fire Shutter Audio/Visual Panel, delay and split level drop with a 24 volt brake release gravity fail safe system.
View The Fire Rated Roller Shutter Image Gallery